Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Biomed Microdevices ; 26(2): 21, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558326

RESUMO

Kirigami is one of the interesting paper art forms and the modified sub-class of origami. Kirigami paper art is widely employed in a variety of applications, and it is currently being used in biosensors because of its outstanding advantages. This is the first study on the use of a Kirigami-based aptasensor for DENV (Dengue virus)-antigen detection. In this study, the kirigami approach has been utilized to develop a stretchable, movable, and flexible sensor. The constructed stretchable-kirigami electrode helps in adjusting the connection of electrodes without disturbing the electrochemical cell zone during the experiment. To increase the sensitivity of this biosensor we have synthesized Ag-NPs (Silver nanoparticles) via chemical methods and characterized their results with the help of TEM & UV-Vis Spectroscopy. Different electrochemical approaches were used to validate the sensor response i.e., CV (Cyclic voltammetry) and LSV (Linear sweep voltammetry), which exhibited great detection capability towards dengue virus with the range of 0.1 µg/ml to 1000 µg/ml along with a detection limit of 0.1 µg/ml and showing no reactivity to the chikungunya virus antigen, making it more specific to the DENV antigen. Serum (healthy-human) was also successfully applied to validate the results of the constructed aptasensor. Integration of the Kirigami approach form with the electrochemical aptasensor that utilizes a 3-E setup (three-electrode setup) which is referred to as a tripod and collectively called Kirigami-tripod-based aptasensor. Thus, the developed integrated platform improves the sensors capabilities in terms of cost efficiency, high stretchability, and sensitivity.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Dengue , Nanopartículas Metálicas , Humanos , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Aptâmeros de Nucleotídeos/química , Ouro/química , Prata/química , Técnicas Biossensoriais/métodos , Eletrodos , Dengue/diagnóstico , Limite de Detecção
2.
ACS Appl Bio Mater ; 7(4): 2299-2308, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38476032

RESUMO

Smartphones' widespread availability and worldwide connection are advancing the idea of mobile-based healthcare and promise to transform the business of biosensors. Biosensors based on smartphones have been investigated in several ways, including employing a smartphone in place of a detector or as an instrumental interface. The current work demonstrates the first successful detection of dengue virus using a smartphone-based pocket sensor combined with a wireless potentiostat. The platform developed comprises a smartphone, a wireless portable potentiostat, an Android app, and a three-electrode setup. The combination of portable diagnostic with electronic application is referred to as "Portronicx", and this is the first time that the term "Portronicx" has been used in a dengue sensor, so the current study has the potential to be commercialized in the market with the tag line "Portronicx-commercialization" in the future. Miniaturization improves alternative setup options in terms of instrument size, affordability, mobility, touch-mobile display, and design versatility. The current work proved the excellent combination of a wireless potentiostat with an aptasensor to detect dengue antigen within 20 s with good LOD (0.1 µg/mL) and easy to carry in their pockets. The created platform also performed effectively in human serum. This study replaced all of the instruments with a lightweight touch smartphone, paving the way for the production of fifth-generation electrochemical aptasensors, with potential implications for healthcare applications on the verge of commercialization.


Assuntos
Técnicas Biossensoriais , Dengue , Humanos , Smartphone , Eletrodos , Dengue/diagnóstico
3.
Micromachines (Basel) ; 15(3)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38542559

RESUMO

Ketamine is one of the most commonly abused drugs globally, posing a severe risk to social stability and human health, not only it is being used for recreational purposes, but this tasteless, odourless, and colourless drug also facilitates sexual assaults when it is mixed with drinks. Ketamine abuse is a threat for safety, and this misuse is one of the main uses of the drug. The crucial role of ketamine detection is evident in its contributions to forensic investigations, law enforcement, drug control, workplace integrity, and public health. Electrochemical sensors have gained considerable interest among researchers due to their various advantages, such as low cost and specificity, and particularly screen-printed paper-based electrode (SPBE) biosensors have gained attention. Here, we reported an ePAD (electrochemical paper-based analytical device) for detecting the recreational drug ketamine. The advantages of using a paper-based electrode are that it reduces the electrode's production costs and is disposable and environmentally friendly. At the same time, nanographite sheets (NGSs) assisted in amplifying the signals generated in the cyclic voltammetry system when ketamine was present. This ePAD was developed by immobilizing a ketamine aptamer on NGS electrodes. The characterization of proper synthesized NGSs was performed by Scanning Electron Microscopy (SEM), XRD (X-ray Diffraction), Fourier-transform infrared spectroscopy (FTIR), and UV-Vis spectroscopy. Electrochemical techniques, including cyclic voltammetry (CV) and linear sweep voltammetry (LSV), were employed to validate the results and confirm each attachment. Furthermore, the versatility of the proposed sensor was explored in both alcoholic and non-alcoholic beverages. The developed sensor showed a low LOD of about 0.01 µg/mL, and the linear range was between 0.01 and 5 µg/mL. This approach offers a valid diagnostic technique for onsite service with minimal resources. This cost effective and portable platform offers desirable characteristics like sensitivity and selectivity and can also be used for POC (point of care) testing to help in the quick identification of suspicious samples and for testing at trafficking sites, amusement parks, and by the side of the road.

4.
Sensors (Basel) ; 24(3)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38339518

RESUMO

There is currently a lot of interest in the construction of point-of-care devices stemming from paper-based origami biosensors. These devices demonstrate how paper's foldability permits the construction of sensitive, selective, user-friendly, intelligent, and maintainable analytical devices for the detection of several ailments. Herein, the first example of the electrochemical aptasensor-based polyvalent dengue viral antigen detection using the origami paper-folding method is presented. Coupling it with an aptamer leads to the development of a new notation known as OBAs, or origami-based aptasensor, that presents a multitude of advantages to the developed platform, such as assisting in safeguarding the sample from air-dust particles, providing confidentiality, and providing a closed chamber to the electrodes. In this paper, gold-decorated nanocomposites of zinc and graphene oxide (Au/ZnO/GO) were synthesized via the chemical method, and characterization was conducted by Scanning Electron Microscope, Transmission Electron Microscope, UV-Vis, and XRD which reveals the successful formation of nanocomposites, mainly helping to enhance the signal and specificity of the sensor by employing aptamers, since isolation and purification procedures are not required. The biosensor that is being demonstrated here is affordable, simple, and efficient. The reported biosensor is an OBA detection of polyvalent antigens of the dengue virus in human serum, presenting a good range from 0.0001 to 0.1 mg/mL with a limit of detection of 0.0001 mg/mL. The reported single-folding ori-aptasensor demonstrates exceptional sensitivity, specificity, and performance in human serum assays, and can also be used for the POC testing of various viral infections in remote areas and underdeveloped countries, as well as being potentially effective during outbreaks. Highlights: (1) First report on origami-based aptasensors for the detection of polyvalent antigens of DENV; (2) In-house construction of low-cost origami-based setup; (3) Gold-decorated zinc/graphene nanocomposite characterization was confirmed via FESEM/UV-Vis/FTIR; (4) Cross-reactivity of dengue-aptamer has been deduced; (5) Electrochemical validation was conducted through CV.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Vírus da Dengue , Dengue , Grafite , Nanocompostos , Humanos , Técnicas Eletroquímicas/métodos , Grafite/química , Nanocompostos/química , Técnicas Biossensoriais/métodos , Dengue/diagnóstico , Ouro/química , Zinco , Aptâmeros de Nucleotídeos/química , Limite de Detecção
5.
Biosensors (Basel) ; 13(10)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37887127

RESUMO

Illicit drug misuse has become a widespread issue that requires continuous drug monitoring and diagnosis. Wearable electrochemical drug detection devices possess the potential to function as potent screening instruments in the possession of law enforcement personnel, aiding in the fight against drug trafficking and facilitating forensic investigations conducted on site. These wearable sensors are promising alternatives to traditional detection methods. In this study, we present a novel wearable electrochemical glove-based analytical device (eGAD) designed especially for detecting the club drug, methamphetamine. To develop this sensor, we immobilized meth aptamer onto silver nanoparticle (AgNPs)-modified electrodes that were printed onto latex gloves. The characteristics of AgNPs, including their shape, size and purity were analysed using FTIR, SEM and UV vis spectrometry, confirming the successful synthesis. The developed sensor shows a 0.1 µg/mL limit of detection and 0.3 µg/mL limit of quantification with a linear concentration range of about 0.01-5 µg/mL and recovery percentages of approximately 102 and 103%, respectively. To demonstrate its applicability, we tested the developed wearable sensor by spiking various alcoholic and non-alcoholic drink samples. We found that the sensor remains effective for 60 days, making it a practical option with a reasonable shelf-life. The developed sensor offers several advantages, including its affordability, ease of handling and high sensitivity and selectivity. Its portable nature makes it an ideal tool for rapid detection of METH in beverages too.


Assuntos
Nanopartículas Metálicas , Metanfetamina , Dispositivos Eletrônicos Vestíveis , Nanopartículas Metálicas/química , Prata/química , Eletrodos , Técnicas Eletroquímicas/métodos
6.
Sensors (Basel) ; 23(12)2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37420685

RESUMO

We present the development of an electrochemical paper-based analytical device (ePAD) for the detection of methamphetamine. Methamphetamine is a stimulant that young people use as an addictive narcotic, and it must be detected quickly since it may be hazardous. The suggested ePAD has the advantages of being simple, affordable, and recyclable. This ePAD was developed by immobilizing a methamphetamine-binding aptamer onto Ag-ZnO nanocomposite electrodes. The Ag-ZnO nanocomposites were synthesized via a chemical method and were further characterized via scanning electron microscopy, Fourier transform infrared spectroscopy, and UV-vis spectrometry in terms of their size, shape, and colloidal activity. The developed sensor showed a limit of detection of about 0.1 µg/mL, with an optimum response time of about 25 s, and its extensive linear range was between 0.01 and 6 µg/mL. The application of the sensor was recognized by spiking different beverages with methamphetamine. The developed sensor has a shelf life of about 30 days. This cost-effective and portable platform might prove to be highly successful in forensic diagnostic applications and will benefit those who cannot afford expensive medical tests.


Assuntos
Metanfetamina , Nanocompostos , Óxido de Zinco , Humanos , Adolescente , Óxido de Zinco/química , Prata/química , Nanocompostos/química , Eletrodos , Técnicas Eletroquímicas/métodos
7.
ACS Appl Bio Mater ; 6(4): 1368-1379, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36926800

RESUMO

Integrating electronic applications with paper, placed next to or below printed images or graphics, can further expand the possible uses of paper substrates. Consuming paper as a substrate in the field of electronics can lead to significant innovations toward papertronics applications as paper comprises various advantages like being disposable, inexpensive, biodegradable, easy to handle, simple to use, and easily available. All of these advantages will definitely spur the advancement of the electronics field, but unfortunately, putting electronics on paper is not an easy task because, compared to plastics, the paper surface is not just rough but also porous. For example, in the case of lateral flow assay testing the sensor response is delayed if the pore size of the paper is enormous. This might be a disadvantage for most electrical devices printed directly on paper. Still, some methods make it compatible when fit with a rough, absorbent surface of the paper. Building electronic devices on a standard paper substrate have sparked much interest because of its lightweight, environmental friendliness, minimal cost, and simple fabrication. A slew of improvements have been achieved in recent years to make paper electronics perform better in various applications, including transistors, batteries, and displays. In addition, flexible electronics have gained much interest in human-machine interaction and wireless sensing. This review briefly examines the origins and fabrication of paper electronics and then moves on to applications and exciting possible paths for paper-based electronics.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Região de Recursos Limitados , Eletrônica , Fontes de Energia Elétrica
8.
Micromachines (Basel) ; 13(12)2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36557336

RESUMO

Zika virus (ZIKV), a positive-sense single-stranded RNA virus, has been declared as the cause of a 'worldwide public health emergency' by the WHO since the year 2016. In cases of acute infections, it has been found to cause Guillain-Barre syndrome and microcephaly. Considering the tropical occurrence of the infections, and the absence of any proper treatments, accurate and timely diagnosis is the only way to control this infectious disease. Currently, there are many diagnostic methods under investigation by the scientific community, but they have some major limitations, such as high cost, low specificity, and poor sensitivity. To overcome these limitations, we have presented a low-cost, simple-to-operate, and portable diagnosis system for its detection by utilizing silver nanoparticles. silver nanoparticles were synthesized via chemical methods and characterization was confirmed by UV/TEM and XRD. The paper platform was synthesized using a graphene-based conductive ink, methylene blue as the redox indicator, and a portable potentiostat to perform the cyclic voltammetry to ensure true point-of-care availability for patients in remote areas.

9.
Micromachines (Basel) ; 13(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36363867

RESUMO

A notable diagnostic for the detection of hemolytic diseases is bilirubin, a by-product of haemoglobin breakdown. The concentration of bilirubin ranges from 0.3 to 1.9 mg in 100 mL of blood. Low blood bilirubin levels are associated with a greater risk of coronary heart disease and anaemia. Hyperbilirubinemia results from a serum bilirubin level of more than 2.5 mg/100 mL. Therefore, it is very crucial to check the serum bilirubin level. Analytical equipment for point-of-care testing must be portable, small, and affordable. A unique method is used to detect bilirubin selectively using paper-based screen-printed carbon electrodes that were covalently linked with nanoparticles, that serves as a key biomarker for jaundice. In order to create an electrochemical biosensor, bilirubin oxidase was immobilised on electrodes modified with AgNPs. The morphology of Ag nanoparticles in terms of size and shape was determined using both UV- Vis Spectroscopy and transmission electron microscopy (TEM). The biosensor's analytical response was assessed using potentiostat (Cyclic voltammetry (CV) and linear sweep voltammetry (LSV)). The developed paper-based sensor provided optimum feedback and a broad linear range of 1 to 9 µg/mL for bilirubin, with a lower LOD of 1 µg/mL. Through tests of bilirubin in artificial blood serum, the viability is confirmed. The method that is being used makes it possible to create and use an inexpensive, miniature electrochemical sensor.

10.
Nanomaterials (Basel) ; 12(19)2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36234412

RESUMO

The advent of nanotechnology has initiated a profound revolution in almost all spheres of technology. The electronics industry is concerned with the ongoing miniaturization of devices and as such requires packaging technologies that will make the devices more compact and resilient. 3D packaging, system in package, and system on chip are the various packaging techniques that utilize nanoscale components for their implementation. The active components of the ICs have kept pace with Moore's law, but the passive components have proven an impediment in the race for miniaturization. Moreover, the toxic effects and nano-scale problems associated with conventional soldering techniques have entailed the active involvement of nanotechnology in the search for answers. Recent advances in these fields and the diverse nanomaterials which are being employed to resolve these issues have been discussed in detail.

11.
Sens Int ; 3: 100197, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35935464

RESUMO

Covid-19 is a dreadful pandemic of the 21st century that has created fear among people, affected the whole world, and taken thousands of lives. It infects the respiratory system and causes flu-type symptoms. According to the WHO reports, 2,082,745 deaths and 96,267,473 confirmed cases were perceived all around the globe till January 22, 2021. The significant roots of transmission are inhalation and direct contact with the infected surface. Its incubation period is 2-14 days and remains asymptomatic in most people. However, no treatment and vaccine are available for the people, so preventive measures like social distancing, wearing personal protective equipment (PPE), and frequent hand-washing are the practical and only options for cure. It has affected every sector of the world, whether it is trade or health all around the world. There is high demand for diagnostic tools as high-scale and expeditious testing is crucial for controlling disease spread; thus, detection methods play an essential role. Like flu, Covid-19 is also detected through RT-PCR, as the World Health Organization (WHO) suggested, but it is time taking and expensive method that many countries cannot afford. A vaccine is a crucial aspect of eradicating disease, and for SARS-CoV-2), plasma therapy and antibiotics therapy are used in the early spreading phase. The later stage involves forming a vaccine based on spike protein, N-protein, and whole-viral antigen that effectively immunizes the population worldwide until herd immunity can be achieved. In this review, we will discuss all possible and developed techniques for identifying SARS-CoV-2 and make a comparison of their specificity, selectivity, and cost; thus, we choose an appropriate method for fast, reliable, and pocket-friendly detection.

12.
Biosensors (Basel) ; 12(8)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-36004979

RESUMO

Many emerging technologies have the potential to improve health care by providing more personalized approaches or early diagnostic methods. In this review, we cover smartphone-based multiplexed sensors as affordable and portable sensing platforms for point-of-care devices. Multiplexing has been gaining attention recently for clinical diagnosis considering certain diseases require analysis of complex biological networks instead of single-marker analysis. Smartphones offer tremendous possibilities for on-site detection analysis due to their portability, high accessibility, fast sample processing, and robust imaging capabilities. Straightforward digital analysis and convenient user interfaces support networked health care systems and individualized health monitoring. Detailed biomarker profiling provides fast and accurate analysis for disease diagnosis for limited sample volume collection. Here, multiplexed smartphone-based assays with optical and electrochemical components are covered. Possible wireless or wired communication actuators and portable and wearable sensing integration for various sensing applications are discussed. The crucial features and the weaknesses of these devices are critically evaluated.


Assuntos
Técnicas Biossensoriais , Smartphone , Biomarcadores/análise , Técnicas Biossensoriais/métodos , Atenção à Saúde , Sistemas Automatizados de Assistência Junto ao Leito
13.
Int J Biol Macromol ; 217: 435-448, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-35817236

RESUMO

The virus known as Japanese Encephalitis (JEV) is among the common viral persisting Encephalitis caused by Flavivirus around the Globe, especially in Southeast Asian nations. JEV may be a leading reason for neurological illness in humans, with an estimated 70,000 human cases and 10,000 fatalities per annum. The conventional methods like PRNT (Plaque Reduction Neutralization Test), ELISA (Enzyme-linked immunosorbent assay) RT-PCR (reverse transcription-polymerase chain reaction), and virus isolation are few commercial tests being availed these days, but they have a variety of drawbacks, including being extremely expensive, time-consuming, and requiring expertise. Therefore, researches are being made in the development of improved inexpensive, shorter, sensitive, and time-saving strategies to diagnose the Japanese Encephalitis Virus. A number of these researches encompass the employment of immunosensors, electrochemical sensors and along with the applications of nanotechnology to create highly sensitive detecting device. This review article is based on contemporary breakthroughs in diagnosing Japanese Encephalitis Virus, which are crucial in severing the connection between the propagation of zoonotic disease into the current race, where humans function as dead-end hosts.


Assuntos
Técnicas Biossensoriais , Vírus da Encefalite Japonesa (Espécie) , Encefalite Japonesa , Encefalite Japonesa/diagnóstico , Humanos , Imunoensaio , Sensibilidade e Especificidade
14.
3 Biotech ; 12(6): 141, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35664651

RESUMO

The recent emergence of respiratory viruses especially COVID-19 and swine flu has underscored the need for robust and bedside detection methods. Swine flu virus is a very infectious virus of the respiratory system. Timely detection of this virus with high specificity and sensitivity is crucial for reducing morbidity as well as mortality. Cloning of gene segments into a non-infectious agent helps in the development of detection methods, vaccine development, and other studies. In this study, cloning was used to develop a biosensor for H1N1 pdm09 detection. A segment of the hemaglutinin gene was cloned in a vector and characterized with the help of colony touch PCR and blue-white screening. The recombinant plasmid was extracted, and the gene segment was confirmed with the help of HA-specific primers. A 5' amine group-attached hemagglutinin (HA) gene-specific DNA probe was immobilized on the working gold electrode surface to make a quick, specific, reliable, and sensitive detection method for H1N1pdm09 virus in human nasal swab samples. The HA probe was immobilized on the cysteine applied gold electrode of the screen-printed electrode through 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). Differential pulse voltammetry was performed with the help of methylene blue, which is a redox indicator for the detection of single-stranded cloned HA gene segment. The developed sensor depicted high sensitivity for the H1N1 influenza virus with a detection limit of 0.6 ng ssDNA/6 µl of the cloned HA sample. Specificity was also checked using H3N2 virus, N. meningitides, influenza A and positive H1N1pdm09 samples.

15.
Sensors (Basel) ; 22(11)2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35684847

RESUMO

Several illnesses that are chronic and acute are becoming more relevant as the world's aging population expands, and the medical sector is transforming rapidly, as a consequence of which the need for "point-of-care" (POC), identification/detection, and real time management of health issues that have been required for a long time are increasing. Biomarkers are biological markers that help to detect status of health or disease. Biosensors' applications are for screening for early detection, chronic disease treatment, health management, and well-being surveillance. Smart devices that allow continual monitoring of vital biomarkers for physiological health monitoring, medical diagnosis, and assessment are becoming increasingly widespread in a variety of applications, ranging from biomedical to healthcare systems of surveillance and monitoring. The term "smart" is used due to the ability of these devices to extract data with intelligence and in real time. Wearable, implantable, ingestible, and portable devices can all be considered smart devices; this is due to their ability of smart interpretation of data, through their smart sensors or biosensors and indicators. Wearable and portable devices have progressed more and more in the shape of various accessories, integrated clothes, and body attachments and inserts. Moreover, implantable and ingestible devices allow for the medical diagnosis and treatment of patients using tiny sensors and biomedical gadgets or devices have become available, thus increasing the quality and efficacy of medical treatments by a significant margin. This article summarizes the state of the art in portable, wearable, ingestible, and implantable devices for health status monitoring and disease management and their possible applications. It also identifies some new technologies that have the potential to contribute to the development of personalized care. Further, these devices are non-invasive in nature, providing information with accuracy and in given time, thus making these devices important for the future use of humanity.


Assuntos
Dispositivos Eletrônicos Vestíveis , Idoso , Biomarcadores , Gerenciamento Clínico , Nível de Saúde , Humanos , Monitorização Fisiológica
16.
Biosensors (Basel) ; 12(2)2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35200347

RESUMO

In this study, we report on a novel aptasensor based on an electrochemical paper-based analytical device (ePAD) that employs a tungsten disulfide (WS2)/aptamer hybrid for the detection of Listeria monocytogenes. Listeria is a well-known causative pathogen for foodborne diseases. The proposed aptasensor signifies many lucrative features which include simple, cost-effective, reliable, and disposable. Furthermore, the use of an aptamer added more advantageous features in the biosensor. The morphological, optical, elemental composition, and phase properties of the synthesized tungsten disulfide (WS2) nanostructures were characterized by field-emission scanning electron microscopy (FESEM), RAMAN spectroscopy, photoluminescence (PL), and X-ray diffraction (XRD), while electrochemical impedance spectroscopy was performed to corroborate the immobilization of aptamer and to assess the L. monocytogenes sensing performance. The limit of detection (LoD) and limit of quantification (LoQ) of the aptasensor was found to be 10 and 4.5 CFU/mL, respectively, within a linear range of 101-108 CFU/mL. The proposed sensor was found to be selective solely towards Listeria monocytogenes in the presence of various bacterial species such as Escherichia coli and Bacillus subtilis. Validation of the aptasensor operation was also evaluated in real samples by spiking them with fixed concentrations (101, 103, and 105) of Listeria monocytogenes, thereby, paving the way for its potential in a point-of-care scenario.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Listeria monocytogenes , Nanoestruturas , Sulfetos/química , Compostos de Tungstênio/química , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos , Escherichia coli/química , Limite de Detecção
17.
Environ Sci Pollut Res Int ; 29(6): 8091-8108, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34841487

RESUMO

Viruses are the potential cause of several diseases including novel corona virus-19, flu, small pox, chicken pox, acquired immunodeficiency syndrome, severe acute respiratory syndrome etc. The objectives of this review article are to summarize the reasons behind the epidemics caused by several emerging viruses and bacteria, how to control the infection and preventive strategies. We have explained the causes of epidemics along with their preventive measures, the impact of lockdown on the health of people and the economy of a country. Several reports have revealed the transmission of infection during epidemic from the contact of an infected person to the public that can be prevented by implementing the lockdown by the government of a country. Though lockdown has been considered as one of the significant parameters to control the diseases, however, it has some negative consequences on the health of people as they can be more prone to other ailments like obesity, diabetes, cardiac problems etc. and drastic decline in the economy of a country. Therefore, the transmission of diseases can be prevented by warning the people about the severity of diseases, avoiding their public transportation, keeping themselves isolated, strictly following the guidelines of lockdown and encouraging regular exercise.


Assuntos
COVID-19 , Controle de Doenças Transmissíveis , Exercício Físico , Humanos , SARS-CoV-2
18.
Biosensors (Basel) ; 13(1)2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36671836

RESUMO

We present, for the very first time, the fabrication and electrochemical characterization of a paper-based experimental platform for dengue virus analysis. The paper-based device incorporates a screen-printing technology with the help of black carbon conductive ink. The paper-based device utilizes two styles of electrode setups, i.e., the two-electrode system and three-electrode system, and both setups effectively detected the dengue virus with an LOD of 0.1 µg/mL; however, these paper electrodes exhibit various current ranges, and the created sensor was encompassed and compared in this research based on current response. It is observed that the three-electrode system has a substantially higher current range, ranging from 55.53 µA to 322.21 µA, as compared to the two-electrode system, which has a current range of 0.85 µA to 4.54 µA. According to this study, the three-electrode system displayed a good range of current amplification that is roughly 50 times higher than the two-electrode system, which had a weak current response. As a result, the three-electrode method has emerged as a viable option for the very sensitive detection of the dengue virus, as well as for the diagnosis of other diseases.


Assuntos
Técnicas Biossensoriais , Vírus da Dengue , Técnicas Biossensoriais/métodos , Condutividade Elétrica , Eletrodos , Impressão , Técnicas Eletroquímicas/métodos , Limite de Detecção
19.
ACS Appl Bio Mater ; 4(2): 1178-1190, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34192244

RESUMO

Ongoing pandemic coronavirus (COVID-19) has affected over 218 countries and infected 88,512,243 and 1,906,853 deaths reported by Jan. 8, 2021. At present, vaccines are being developed in Europe, Russia, USA, and China, although some of these are in phase III of trials, which are waiting to be available for the general public. The only option available now is by vigorous testing, isolation of the infected cases, and maintaining physical and social distances. Numerous methods are now available or being developed for testing the suspected cases, which may act as carriers of the virus. In this review, efforts have been made to discuss the conventional as well as fast, rapid, and efficient testing methods developed for the diagnosis of 2019-nCoV.Testing methods can be based on the sensing of targets, which include RNA, spike proteins and antibodies such as IgG and IgM. Apart from the development of RNA targeted PCR, antibody and VSV pseudovirus neutralization assay along with several other diagnostic techniques have been developed. Additionally, nanotechnology-based sensors are being developed for the diagnosis of the virus, and these are also discussed.


Assuntos
Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , SARS-CoV-2/química , Glicoproteína da Espícula de Coronavírus/análise , Animais , Anticorpos Imobilizados/imunologia , Anticorpos Neutralizantes/análise , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Grafite/química , Humanos , Nanopartículas Metálicas/química , Nanotecnologia/métodos , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia
20.
Plant Pathol J ; 37(3): 291-298, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34111918

RESUMO

False smut caused by Ustilaginoidea virens is an important rice fungal disease that significantly decreases its production. In the recent past, conventional methods have been developed for its detection that is time-consuming and need high-cost equipments. The research and development in nanotechnology have made it possible to assemble efficient recognition interfaces in biosensors. In this study, we present a simple, sensitive, and selective oxidized graphene-based geno-biosensor for the detection of rice false smut. The biosensor has been developed using a probe DNA as a biological recognition element on paper electrodes, and oxidized graphene to enhance the limit of detection and sensitivity of the sensor. Probe single-stranded DNA (ssDNA) and target ssDNA hybridization on the interface surface has been quantitatively measured with the electrochemical analysis tools namely, cyclic voltammetry, and linear sweep voltammetry. To confirm the selectivity of the device, probe hybridization with non-complementary ssDNA target has been studied. In our study, the developed sensor was able to detect up to 10 fM of target ssDNA. The paper electrodes were employed to produce an effective and cost-effective platform for the immobilization of the DNA and can be extended to design low-cost biosensors for the detection of the other plant pathogens.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA